Back to top
Phase Reversal Failure Relay
Phase Reversal Failure Relay

Phase Reversal Failure Relay

Price 250 INR/ Piece

MOQ : 1 , , Piece

Phase Reversal Failure Relay Specification

  • Protect Feature
  • Phase reversal and failure protection
  • Ambient Temperature
  • -10C to +55C
  • Coil Power
  • Approx. 2W
  • Working Temperature
  • -10C to +50C
  • Contact Material
  • AgCdO
  • Power Consumption
  • Less than 3VA
  • Coil Voltage
  • 415V AC
  • Contact Resistance
  • <50 m
  • Mechanical Life
  • >1,000,000 operations
  • Dielectiric Strength
  • 2kV AC for 1 min
  • Contact Form
  • SPDT
  • Product Type
  • Phase Reversal Failure Relay
  • Insulation Resistance
  • 100 M min (at 500V DC)
  • Theory
  • Electromagnetic Relay
  • Usage
  • Protection of three-phase electrical motors and equipment from phase reversal and failure
  • Contact Load
  • 5A at 230V AC
  • Operate Time
  • Less than 300 ms
  • Terminal Type
  • Screw Type
  • Rated Voltage
  • 415V AC
  • Supply Terminal
  • L1, L2, L3
  • Size
  • Standard
  • Color
  • Black
  • Dimension (L*W*H)
  • 90 mm x 22.5 mm x 65 mm
  • Weight
  • Approx. 150 g
 

Phase Reversal Failure Relay Trade Information

  • Minimum Order Quantity
  • 1 , , Piece
  • Supply Ability
  • 1000 Pieces Per Month
  • Delivery Time
  • 3 Week
 

About Phase Reversal Failure Relay

 We are indulged in providing a distinct stock of Phase Reversal Failure Relay in the market. It is suitable for monitoring incoming 3-phase supply from Mains. It finds the application for monitoring electricity distribution line. Phase Reversal Failure Relay measure the sequence of the phases when being switched on. It is also suitable to give protection to the motor from overheating. It increases the motor life by preventing the motor from rotating in the wrong direction.

   

Technical details

System

415 V, 3Ph, 50Hz.

Voltage Variation

+10% and -20% of system Voltage

Auxiliary supply

1 set of 1N/o and 1N/c

Relay contacts

Change over contacts.

Rating of relay contacts

AC - 400 VA (Resistive) or 220 VA (Inductive) with Max 5 amps at 415 volts.





Reliable Phase Protection for Industrial Motors

This relay ensures continuous operation and damage prevention by detecting phase reversal or failure in three-phase systems. Its quick reaction and automatic reset help maximize equipment lifespan and minimize downtime.


User-Friendly Design and Installation

With standard DIN rail mounting, screw terminals, and a visible LED indicator, the relay offers simple installation and operation. Its robust construction and compliance with IS/IEC standards guarantee long-term reliability in varied industrial settings.


Built for Versatile Environments

The device functions efficiently within a wide range of storage and operating temperatures and is resistant to high humidity. Its ABS plastic enclosure and standard size facilitate easy integration in diverse control panels.

FAQs of Phase Reversal Failure Relay:


Q: How does the Phase Reversal Failure Relay protect three-phase motors?

A: The relay continuously monitors the supply phases (L1, L2, L3). If a phase reversal or failure occurs, it immediately activates its output contact to disconnect or signal the protection system, preventing motor damage.

Q: What is the correct installation process for this relay?

A: Mount the relay on a DIN rail inside the control panel and connect the supply terminals (L1, L2, L3) using the screw-type terminals. Ensure proper wiring as per the product manual before applying power.

Q: When will the relay automatically reset itself?

A: The automatic reset occurs after the correct phase sequence and supply is restored. The relay recognizes the normal condition and resets itself without requiring manual intervention.

Q: Where can this relay be used effectively?

A: It is ideal for industrial or commercial applications where three-phase motors and sensitive equipment require reliable protection against phase reversal and failure, such as pump stations, HVAC systems, and manufacturing plants.

Q: What benefits does the LED status indicator provide?

A: The LED indicator visibly displays the relays operational status, allowing technicians to quickly check if the relay is powered and whether a fault condition is present, thus aiding in efficient troubleshooting.

Q: How does compliance with IS/IEC Standards benefit users?

A: Adhering to IS/IEC standards ensures the relay meets quality, safety, and performance benchmarks, providing reliable and consistent protection in electrical installations as expected in global and Indian markets.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Phase Failure Relay Category

415 V Phase Failure Relay

415 V Phase Failure Relay

Price 250 INR / Piece

Minimum Order Quantity : 1 Piece

Rated Voltage : 415 V AC

Insulation Resistance : >20 M (at 500 VDC)

Protect Feature : Other, Phase Failure, Phase Sequence, Under/Over Voltage

Theory : Other , Electromagnetic Relay

Phase Failure Relay

Phase Failure Relay

Price 250 INR / Piece

Minimum Order Quantity : 1 Piece

Rated Voltage : 415V AC

Insulation Resistance : >=100M at 500V DC

Protect Feature : Other, Phase Failure, Phase Sequence, Phase Unbalance

Theory : Other , Electromagnetic Relay