Back to top
Earth Leakage Relay Elrbif
Earth Leakage Relay Elrbif

Earth Leakage Relay Elrbif

Price 250 INR/ Piece

MOQ : 1 , , Piece

Earth Leakage Relay Elrbif Specification

  • Ambient Temperature
  • -10C to 55C
  • Contact Resistance
  • < 50m
  • Contact Form
  • 1 Changeover (SPDT)
  • Mechanical Life
  • > 10,000 operations
  • Coil Power
  • < 2W
  • Protect Feature
  • Earth leakage detection
  • Working Temperature
  • -10C to 50C
  • Coil Voltage
  • 230V AC
  • Contact Material
  • Silver alloy
  • Power Consumption
  • < 2VA
  • Dielectiric Strength
  • 2000V for 1 min
  • Product Type
  • Earth Leakage Relay
  • Insulation Resistance
  • > 100M at 500V DC
  • Theory
  • Electromagnetic relay
  • Usage
  • Earth leakage protection
  • Contact Load
  • 5A 230V AC
  • Operate Time
  • 300ms
  • Terminal Type
  • Screw terminals
  • Rated Voltage
  • 230V AC
  • Supply Terminal
  • L/N terminals
  • Size
  • Standard compact
  • Color
  • Black and silver
  • Dimension (L*W*H)
  • 90mm x 36mm x 65mm
  • Weight
  • 180g
 

Earth Leakage Relay Elrbif Trade Information

  • Minimum Order Quantity
  • 1 , , Piece
  • Supply Ability
  • 1000 Pieces Per Month
  • Delivery Time
  • 3 Week
 

About Earth Leakage Relay Elrbif

With a constant support of deft experts, we are offering a unique range of  Earth Leakage Relay Elrbif to our respected consumers. It is a device used to sense earth leakages. In addition to this, provided device is normally used in low voltage circuits only. It creates a magnetic field proportional to the current flow. Earth Leakage Relay Elrbif can be connected to give an alarm as to initiate all the terminals.






Adjustable Sensitivity for Versatile Protection

With sensitivity settings adjustable from 30mA to 3A, the ELRBIF Earth Leakage Relay suits a wide range of protection requirements in both industrial and commercial applications. This flexibility makes it ideal for different load conditions and fault sensitivity levels, enhancing safety and operational confidence in critical distribution systems.


Easy Installation and Reliable Operation

The ELRBIF relay offers DIN rail and panel mounting options for seamless integration into new or existing systems. Clearly marked screw terminals and LED status indicators simplify installation and allow users to monitor relay status at a glance, ensuring ease of maintenance and consistent functionality over time.

FAQs of Earth Leakage Relay Elrbif:


Q: How does the ELRBIF Earth Leakage Relay ensure electrical safety in distribution systems?

A: The ELRBIF relay continuously monitors circuits for earth leakage currents. When the leakage exceeds a preset adjustable threshold (30mA to 3A), it triggers the relay, providing immediate protection by disconnecting the faulty circuit, which helps prevent electrical shocks and fire hazards.

Q: What are the mounting options available for the ELRBIF relay, and where can it be installed?

A: The ELRBIF Earth Leakage Relay supports both DIN rail and panel mounting, making it suitable for a variety of installation environments, including industrial switchboards or commercial control panels.

Q: When should I opt for manual or auto reset functions on this relay?

A: Choose the manual reset when you want to investigate a fault before re-energizing the protected circuit, ideal for high-risk areas. Select auto reset for processes requiring quick recovery where operational continuity is crucial after transient faults.

Q: What usage benefits does the LED status indicator provide?

A: LED status indicators give real-time visual feedback on the relays operational state, alerting users immediately to normal operation, fault conditions, or tripped status, thus enhancing trouble-shooting efficiency and safety management.

Q: How is the ELRBIF relay suitable for environments with fluctuating humidity?

A: Designed to operate efficiently in environments with humidity levels below 85% RH, the ELRBIF ensures dependable earth leakage protection even in challenging electrical rooms or industrial settings.

Q: What is the process for wiring the ELRBIF Earth Leakage Relay?

A: Wiring is straightforwardconnect the supply using L/N (Line/Neutral) terminals and secure all connections with the provided screw terminals. The relay supports 230V AC supply and includes NO (Normally Open) and NC (Normally Closed) outputs for flexible integration with safety circuits.

Q: What are the key benefits of using the ELRBIF relay in industrial and commercial settings?

A: It provides adjustable leakage protection, robust electrical life (>100,000 operations), short circuit withstand up to 6kA, clear operational feedback, and easy installationensuring enhanced safety, minimized downtime, and reliable long-term operation.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Earth Leakage Relay Category

Earth Leakage Relay Type Elrmsmb

Earth Leakage Relay Type Elrmsmb

Price 250 INR / Piece

Minimum Order Quantity : 1 , , Piece

Dimension (L*W*H) : 96mm x 96mm x 60mm

Coil Power : Low Power Consumption

Mechanical Life : Over 100,000 Operations

Contact Form : SPDT

550V ELRMSMB Type Earth Leakage Relay

550V ELRMSMB Type Earth Leakage Relay

Price 250 INR / Piece

Minimum Order Quantity : 1 Piece

Dimension (L*W*H) : 110mm x 70mm x 50mm

Coil Power : 2VA

Mechanical Life : >100,000 operations

Contact Form : SPDT

415V Earth Leakage Relay

415V Earth Leakage Relay

Price 250 INR / Piece

Minimum Order Quantity : 1 Piece

Dimension (L*W*H) : 110 x 75 x 70 mm

Coil Power : 2.5 VA

Mechanical Life : >10 million operations

Contact Form : 1NO + 1NC

Digital Earth Loakage Relay

Digital Earth Loakage Relay

Price 250 INR / Piece

Minimum Order Quantity : 1 Piece

Dimension (L*W*H) : 90mm x 36mm x 65mm

Coil Power : <2VA

Mechanical Life : 1,000,000 Operations

Contact Form : 1 Changeover (SPDT)